This is a simple test to determine whether organic oxygen compounds are present in propylene dichloride (1,2-dichloropropane) and carbon tetrachloride in concentrations greater or less than 0.1 wt-% organic oxygen, using propylene glycol as the organic oxygen reference. Nitrogen and sulfur compounds interfere, while diaryl ethers give a false negative test. These are not serious limitations, since none of these classes of compounds is likely to be present in commercial propylene dichloride or carbon tetrachloride.

Author ASTM
Editor ASTM
Document type Standard
Format File
Confirmation date 2006-04-18
Number of pages 3
Year 1970
Country USA
Keyword ASTM 712;ASTM UOP712;ASTM UOP712;